Blog · Guides
RCD keeps tripping? Why it happens and what to do
You flick a switch, the lights go out, and the RCD in your fuse box has snapped down again. You push it back up, and a few minutes or a few days later it happens again. It is annoying, but an RCD that keeps tripping is doing exactly what it is there for.
What an RCD does
An RCD (residual current device) is a safety switch in your consumer unit, the modern name for a fuse box. It constantly compares the electricity going out on a circuit with the electricity coming back. If some of it is leaking away, through damaged wiring, water, a faulty appliance or a person, it switches the power off in a fraction of a second.
That is why it matters. An RCD is designed to cut the power fast enough to prevent a serious electric shock. When it trips, it has usually found a real problem.
The most common reasons an RCD trips
- A faulty appliance. This is the most common cause by far. Kettles, washing machines, dishwashers, tumble dryers, immersion heaters, fridges and outdoor equipment are frequent culprits, especially as they age.
- Water getting in. Rain getting into an outdoor socket, garden light or outbuilding supply, or a leak reaching a ceiling light or junction box.
- Damaged wiring. A nail or screw through a cable, a cable crushed under flooring, or wiring damaged by rodents.
- Too many small leaks on one RCD. Many modern appliances leak a tiny, harmless amount of current. Add enough of them on one RCD and together they can tip it over its limit.
- An ageing or faulty RCD. Less common, but RCDs do wear out.
RCD tripping at night
If it trips at night, think about what switches on by itself while you sleep: a freezer or fridge compressor, a storage or immersion heater on a timer, a dishwasher or washing machine on delay, outdoor lights on a sensor, or an electric car charging. A fault in one of these often shows itself only when that appliance kicks in.
RCD tripping after heavy rain
Tripping that follows rain points strongly to moisture. Outdoor sockets, garden lighting, supplies to sheds and garden offices, and outside lights are the usual suspects. Damp in walls or a roof leak near lighting can do the same. Do not keep resetting it in wet weather. Water and electricity together are dangerous.
RCD tripping with nothing plugged in
If it still trips with every appliance unplugged, the fault is probably in the fixed wiring itself, or in something wired in permanently, such as an extractor fan, a cooker, an electric shower or a light fitting. This is the point to stop and call an electrician.
Why the RCD trips but not the circuit breaker
Circuit breakers (MCBs) and RCDs look for different problems. A breaker trips when a circuit draws too much current, for example from overloading or a short circuit. An RCD trips when current is leaking somewhere it should not. So when the RCD goes and the breakers stay on, you are almost always looking at a leak to earth, not an overload.
Simple checks you can safely make
These checks help you or your electrician narrow it down. Never remove the cover of your consumer unit or open up sockets and fittings.
- Note what happened. What was switched on, the time of day and the weather. Patterns help find the fault quickly.
- Unplug everything on the circuits that went off, and switch off any appliances with their own switches.
- Reset the RCD once. If it will not stay up with everything unplugged, leave it off and call an electrician.
- If it stays up, plug appliances back in one at a time, waiting a little between each. If it trips when one goes back in, stop using that appliance and have it checked or replaced.
- Leave anything outdoors or wet switched off until it has been looked at.
When to call an electrician straight away
- The RCD will not reset, even with everything unplugged
- There is a burning smell, scorch marks, crackling or buzzing
- Water has got into a light, socket or the consumer unit
- Someone got a tingle or a shock
- It keeps tripping and you cannot find a cause
If you smell burning, see smoke or sparks, or someone has had an electric shock, switch off at the mains if it is safe to do so and get help straight away. In a fire, call 999.
Never do this
- Do not tape, wedge or hold an RCD in the on position
- Do not keep resetting it over and over
- Do not bypass it or ask anyone to remove it
How an electrician finds the fault
An electrician tests each circuit with specialist instruments to measure where current is leaking, then narrows it down to the faulty cable, fitting or appliance. Some faults are found in minutes. Ones that come and go take longer, so your notes about when it trips make a real difference.
If your consumer unit is old, has only one RCD covering the whole house, or still uses rewirable fuses, it may be worth talking about an upgrade. With separate protection on each circuit, one fault no longer plunges the whole house into darkness.
Not yet reviewed by a qualified electrician.